00218012 Revision B (KAK) 7 August, 2000
18
Multiplex Company, Inc.
Fountain Troubleshooting Guide
Troubleshooting Guide
WARNING: Inspection, testing, and repair of elec-
trical equipment should be performed only by
qualified service personnel. The unit should be
unplugged when servicing, except when electri-
cal tests are required.
DANGER: Use extreme care during electrical cir-
cuit tests. Live circuits may be exposed.
Qualifier Probable Cause Corrective Action
Peculiar taste in fin-
ished product.
Section 4: Compressed Air System (continued)
Contaminated Germicidal
Filter on Air Compressor.
Water in Air Accumulator
Tank.
Water Filter contami-
nated.
Replace Germicidal Filter.
Note: This filter is not designed to be cleaned,
but must be replaced when exhausted.
Drain trapped water from tank by removing
Drain Line from top of Automatic Drain. Disas-
semble and clean Automatic Drain. If unit is
not equipped with automatic drain, use pet-
cock to remove water from tank.
Refer to Troubleshooting Section 10: Water
Filter System under Peculiar taste.
No syrup (continued)