Service Bulletin
MOVs field testing
Metal Oxide Varistors installed on the water and carbonated water buttons, on McDonalds style
dispensing towers, are designed to completely absorb electrical spikes keeping them out of the
microprocessor circuit eliminating complaints of:
w Not holding calibration
w Valves flowing by themselves
w Two valves coming on at the same time, etc.
Multiplex has designed a field test procedure that will expose a faulty MOV. This procedure will
also work on the older style capacitors.
The field test procedure:
Depress
separately both the water and soda water button rapidly 5-6 times. While doing this,
watch all other valves. If you notice any dripping or any other valve trying to energize, the MOVs
need to be replaced.
Note: Factory installed MOVs have heat shrink tubes on each terminal leg. Always check to make
sure that heat shrink has not slipped down and is insulating the MOV leg inside the terminal connec-
tor.