60 Part Number 80-1230-9 6/08
17. Use 1/2 of the sanitizer/water solution to sanitize
all removed components. Use a cloth or sponge
to liberally apply the solution to all surfaces of the
removed parts or soak the removed parts in the
sanitizer/water solution. Do not rinse parts after
sanitizing.
18. Use 1/2 of the sanitizer/water solution to sanitize
the bin (or dispenser). Use a cloth or sponge to
liberally apply the solution. Do not rinse the
sanitized areas.
19. Reinstall the removed parts, restore water and
power supply and test run the ice machine.
NOTE: Disconnecting the power supply will activate a
5 minute time delay before the ice machine will start.
The delay will start to time out when power is restored
to the ice machine. This delay period can not be over
ridden.