Part Number 80-1230-9 6/08 231
GEAR BOX REMOVAL
QC0700/QF0800
The evaporator and motor / gearbox are separate
assemblies. Warranty procedures require replacement
of the entire evaporator or motor /gearbox assembly.
Field rebuilding during the warranty period is not
allowed.
1. Disconnect power to the ice machine.
2. Remove water level probes, water reservoir
cover, float valve, water reservoir, ice chute, and
drain tubing (refer to Component Removal).
3. Remove bolts securing foundation coupling to
gear motor assembly.
4. Lift evaporator and rest on top of foundation
coupling.
5. Disconnect line voltage wiring at motor Molex
connector.
6. Remove two screws holding motor speed sensor
and remove sensor.
7. Remove bolts securing gear motor assembly
mounting bracket to base.
8. Remove gear motor assembly from ice machine.
9. Remove coupling, spline hub, keyway, and
mounting bracket from gear motor.