Thank you for selecting a Manitowoc Ice Machine, the dependability leader in ice making equipment and related products.
With proper installation, care and maintenance, your new Manitowoc Ice Machine will provide you with many years of
reliable and economical performance.
S Model
S0850M
Ice Machines
Service
Manual
Part Number 80-1558-3
4/2004
Zobrazit stránku 0
1 2 3 4 5 6 ... 99 100

Shrnutí obsahu

Strany 1 - Ice Machines

Thank you for selecting a Manitowoc Ice Machine, the dependability leader in ice making equipment and related products. With proper installation, care

Strany 2 - Procedural Notices

General Information Section 11-4 Part Number 80-1558-3Owner Warranty Registration CardGENERALThe packet containing this manual also includes warranty

Strany 3 - Table of Contents

Attend A Manitowoc Factory Service School• Improve Your Service Techniques• Network with Your Peers• 4 1/2 Days of Intensive Training on Manitowoc Ice

Strany 4 - Part No. 80-1558-3

Section 2 Installation Instructions Part Number 80-1558-3 2-1Section 2Installation InstructionsGeneralThese instructions are provided to assist the qu

Strany 5 - Part No. 80-1558-3 1-3

Installation Instructions Section 22-2 Part Number 80-1558-3Location of Ice MachineThe location selected for the ice machine must meet the following c

Strany 6 - 1-4 Part No. 80-1558-3

Section 2 Installation Instructions Part Number 80-1558-3 2-3Electrical ServiceGENERALVOLTAGEThe maximum allowable voltage variation is ±10% of the ra

Strany 7 - General Information

Installation Instructions Section 22-4 Part Number 80-1558-3Self-Contained Electrical Wiring ConnectionsSELF CONTAINED ICE MACHINE115/1/60 OR 208-230/

Strany 8 - Accessories

Section 2 Installation Instructions Part Number 80-1558-3 2-5Water Supply and Drain RequirementsWATER SUPPLYLocal water conditions may require treatme

Strany 9 - Model/Serial Number Location

Installation Instructions Section 22-6 Part Number 80-1558-3WATER SUPPLY AND DRAIN LINE SIZING/CONNECTIONSTypical Water Supply Drain Installation!Caut

Strany 10 - Warranty Coverage

Section 2 Installation Instructions Part Number 80-1558-3 2-7Installation Check ListIs the Ice Machine level?Has all of the internal packing been remo

Strany 11 - Installation Instructions

Installation Instructions Section 22-8 Part Number 80-1558-3Before Starting the Ice MachineAll Manitowoc ice machines are factory-operated and adjuste

Strany 12 - Ice Machine Heat of Rejection

Section 3 Ice Machine Operation Part Number 80-1558-3 3-1Section 3Ice Machine OperationComponent Identificationsv3150sv3149Check ValveIce Thickness Pr

Strany 13 - Electrical Service

We reserve the right to make product improvements at any time.Specifications and design are subject to change without notice. Safety NoticesAs you wor

Strany 14 - For United Kingdom Only

Ice Machine Operation Section 33-2 Part Number 80-1558-3Sequence Of OperationNOTE: The toggle switch must be in the ice position and the water curtain

Strany 15 - (Water-Cooled Models)

Section 3 Ice Machine Operation Part Number 80-1558-3 3-3HARVEST SEQUENCE5. Water PurgeThe harvest valve(s) opens at the beginning of the water purge

Strany 16

Ice Machine Operation Section 33-4 Part Number 80-1558-3Operational ChecksGENERALManitowoc ice machines are factory-operated and adjusted before shipm

Strany 17 - Installation Check List

Section 3 Ice Machine Operation Part Number 80-1558-3 3-5HARVEST SEQUENCE WATER PURGEThe harvest sequence water purge adjustment may be used when the

Strany 18 - Part Number 80-1558-3

Ice Machine Operation Section 33-6 Part Number 80-1558-3THIS PAGE INTENTIONALLY LEFT BLANK

Strany 19 - Ice Machine Operation

Section 4 Maintenance Part Number 80-1558-3 4-1Section 4MaintenanceGeneralYou are responsible for maintaining the ice machine in accordance with the i

Strany 20 - Sequence Of Operation

Maintenance Section 44-2 Part Number 80-1558-3Guardian™Slime is a leading cause of ice machine breakdowns and biological growth is a health concern. T

Strany 21 - Part Number 80-1558-3 3-3

Section 4 Maintenance Part Number 80-1558-3 4-3Interior Cleaning and SanitizingGENERALClean and sanitize the ice machine every six months for efficien

Strany 22 - Operational Checks

Maintenance Section 44-4 Part Number 80-1558-3SANITIZING PROCEDUREUse sanitizer to remove algae or slime. Do not use it to remove lime scale or other

Strany 23 - Important

Section 4 Maintenance Part Number 80-1558-3 4-5REMOVAL OF PARTS FOR CLEANING/SANITIZING1. Turn off the electrical and water supply to the ice machine

Strany 24

Part No. 80-1558-3 1-1Table of ContentsSection 1 General InformationModel Numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strany 25 - Maintenance

Maintenance Section 44-6 Part Number 80-1558-31. Water CurtainA. Gently flex the curtain in the center and remove it from the right side.B. Slide the

Strany 26 - Guardian™

Section 4 Maintenance Part Number 80-1558-3 4-73. Water Distribution TubeNOTE: Distribution tube thumbscrews are retained by o-rings to prevent loss.

Strany 27 - Section 4 Maintenance

Maintenance Section 44-8 Part Number 80-1558-3Water Level Probe1. Remove the water trough.2. The water level probe normally does not require removal f

Strany 28

Section 4 Maintenance Part Number 80-1558-3 4-9Water Dump ValveThe water dump valve normally does not require removal for cleaning. To determine if re

Strany 29

Maintenance Section 44-10 Part Number 80-1558-3Evaporator Tray Removal1. Remove the water trough.2. Remove thumbscrew on left side of tray.3. Allow le

Strany 30

Section 4 Maintenance Part Number 80-1558-3 4-11Water Inlet ValveThe water inlet valve normally does not require removal for cleaning. Refer to Sectio

Strany 31

Maintenance Section 44-12 Part Number 80-1558-3Removal from Service/WinterizationGENERALSpecial precautions must be taken if the ice machine is to be

Strany 32

Section 5 Before Calling For Service Part Number 80-1558-3 5-1Section 5Before Calling For ServiceChecklistIf a problem arises during operation of your

Strany 33

Before Calling For Service Section 55-2 Part Number 80-1558-3Safety Limit FeatureIn addition to the standard safety controls, such as the high pressur

Strany 34

Section 6 Electrical System Part Number 80-1558-3 6-1Section 6Electrical SystemEnergized Parts ChartsSELF-CONTAINED WATER-COOLED MODELS1. Initial Sta

Strany 35 - Removing the Front Panel

Table of Contents (continued)1-2 Part No. 80-1558-3Section 3 Ice Machine OperationComponent Identification . . . . . . . . . . . . . . . . . . . . .

Strany 36

Electrical System Section 66-2 Part Number 80-1558-3Wiring Diagram Sequence of Operation SELF-CONTAINED MODELSInitial Start-Up or Start-Up After Autom

Strany 37 - Before Calling For Service

Section 6 Electrical System Part Number 80-1558-3 6-32. REFRIGERATION SYSTEM START-UPThe compressor starts after the 45-second water purge, and it rem

Strany 38 - Safety Limit Feature

Electrical System Section 66-4 Part Number 80-1558-3Freeze Sequence3. PRE-CHILLTo pre-chill the evaporator, the compressor runs for 30 seconds (60 sec

Strany 39 - Electrical System

Section 6 Electrical System Part Number 80-1558-3 6-54. FREEZEThe water pump starts after the pre-chill. An even flow of water is directed across the

Strany 40 - Operation

Electrical System Section 66-6 Part Number 80-1558-3Harvest Sequence5. WATER PURGEThe harvest valve(s) opens at the beginning of the water purge to di

Strany 41 - Section 6 Electrical System

Section 6 Electrical System Part Number 80-1558-3 6-76. HARVESTThe harvest valve(s) remains open and the refrigerant gas warms the evaporator. This ca

Strany 42

Electrical System Section 66-8 Part Number 80-1558-3Automatic Shut-Off7. AUTOMATIC SHUT-OFFWhen the storage bin is full at the end of a harvest cycle,

Strany 43

Section 6 Electrical System Part Number 80-1558-3 6-9Wiring DiagramsThe following pages contain electrical wiring diagrams. Be sure you are referring

Strany 44

Electrical System Section 66-10 Part Number 80-1558-3S0850M - SELF CONTAINED - 1 PHASE SV3130(89)(55)(88)(42)High Pressure CutoutWater ValveHarvest Va

Strany 45

Section 6 Electrical System Part Number 80-1558-3 6-11S0850M - SELF CONTAINED - 3 PHASESV3131(89)(55)(88)(42)High Pressure CutoutWater ValveHarvest Va

Strany 46

Table of Contents (continued)Part No. 80-1558-3 1-3Section 6 Electrical SystemEnergized Parts Charts . . . . . . . . . . . . . . . . . . . . . . . .

Strany 47 - Wiring Diagrams

Electrical System Section 66-12 Part Number 80-1558-3Component Specifications and DiagnosticsMAIN FUSEFunctionThe control board fuse stops ice machine

Strany 48

Section 6 Electrical System Part Number 80-1558-3 6-13SymptomsBin Switch Fails Open• The ice machine will not start with the toggle switch in the ice

Strany 49

Electrical System Section 66-14 Part Number 80-1558-3COMPRESSOR ELECTRICAL DIAGNOSTICSThe compressor will not start or will trip repeatedly on overloa

Strany 50

Section 6 Electrical System Part Number 80-1558-3 6-15PTCR DIAGNOSTICSWhat is a PTCR?A PTCR (or Positive Temperature Coefficient Resistor) is made fro

Strany 51

Electrical System Section 66-16 Part Number 80-1558-3S-Model Automatic Shut-Off and RestartWhen the storage bin is full at the end of a harvest cycle,

Strany 52

Section 6 Electrical System Part Number 80-1558-3 6-17There are other problems that may cause compressor start-up failure with a good PTCR in a new, p

Strany 53

Electrical System Section 66-18 Part Number 80-1558-3DIAGNOSING START COMPONENTSIf the compressor attempts to start, or hums and trips the overload pr

Strany 54

Section 6 Electrical System Part Number 80-1558-3 6-19ELECTRONIC CONTROL BOARDControl BoardSV3129AC LINE VOLTAGE ELECTRICAL PLUG (NUMBERS MARKED ON WI

Strany 55

Electrical System Section 66-20 Part Number 80-1558-3General S-Model control boards use a dual voltage transformer. This means only one control board

Strany 56

Section 6 Electrical System Part Number 80-1558-3 6-21Ice Thickness Probe (Harvest Initiation)HOW THE PROBE WORKSManitowoc’s electronic sensing circui

Strany 57

Table of Contents (continued)1-4 Part No. 80-1558-3Cycle Time/24 Hour Ice Production/Refrigerant Pressure Charts . . . . . . . . . 7-19Refrigerant

Strany 58

Electrical System Section 66-22 Part Number 80-1558-3DIAGNOSING ICE THICKNESS CONTROL CIRCUITRYIce Machine Does Not Cycle Into Harvest When Water Cont

Strany 59

Section 6 Electrical System Part Number 80-1558-3 6-23Water Level Control CircuitryWATER LEVEL PROBE LIGHTThe water level probe circuit can be monitor

Strany 60

Electrical System Section 66-24 Part Number 80-1558-3DIAGNOSING WATER LEVEL CONTROL CIRCUITRYProblem: Water Trough Overfilling During The Freeze Cycle

Strany 61 - Water Level Control Circuitry

Section 6 Electrical System Part Number 80-1558-3 6-25Problem: Water Will Not Run Into The Sump Trough During The Freeze CycleStep 1 Verify water is

Strany 62

Electrical System Section 66-26 Part Number 80-1558-3Diagnosing An Ice Machine That Will Not Run!WarningHigh (line) voltage is applied to the control

Strany 63

Section 6 Electrical System Part Number 80-1558-3 6-27S0850M - SELF CONTAINED - 1 PHASE WITH TERMINAL BOARDSV2071213456

Strany 64

Electrical System Section 66-28 Part Number 80-1558-3THIS PAGE INTENTIONALLY LEFT BLANK

Strany 65

Section 7 . Refrigeration System Part Number 80-1558-3 7-1Section 7.Refrigeration SystemSequence of OperationSELF-CONTAINED WATER -COOLED MODELSFigure

Strany 66

. Refrigeration System Section 77-2 Part Number 80-1558-3Figure 7-2. Self-Contained Harvest Cycle Harvest Cycle Refrigeration SequenceHot gas flows th

Strany 67 - Refrigeration System

Section 7 . Refrigeration System Part Number 80-1558-3 7-3Operational Analysis (Diagnostics)GENERALWhen analyzing the refrigeration system, it is impo

Strany 68

Section 1 General Information Part Number 80-1558-3 1-1Section 1General InformationModel NumbersThis manual covers the following models: NOTE: Model n

Strany 69 - Part Number 80-1558-3 7-3

. Refrigeration System Section 77-4 Part Number 80-1558-3BEFORE BEGINNING SERVICEIce machines may experience operational problems only during certain

Strany 70

Section 7 . Refrigeration System Part Number 80-1558-3 7-5INSTALLATION/VISUAL INSPECTION CHECKLIST WATER SYSTEM CHECKLISTA water-related problem often

Strany 71

. Refrigeration System Section 77-6 Part Number 80-1558-3ICE FORMATION PATTERNEvaporator ice formation pattern analysis is helpful in ice machine diag

Strany 72

Section 7 . Refrigeration System Part Number 80-1558-3 7-73. Extremely Thin at Evaporator InletThere is no ice, or a considerable lack of ice formatio

Strany 73 - Part Number 80-1558-3 7-7

. Refrigeration System Section 77-8 Part Number 80-1558-3SAFETY LIMITSGeneralIn addition to standard safety controls, such as high pressure cut-out, t

Strany 74

Section 7 . Refrigeration System Part Number 80-1558-3 7-9Safety Limit #1Refer to previous page for safety limit operation.Freeze time exceeds 60 minu

Strany 75

. Refrigeration System Section 77-10 Part Number 80-1558-3Safety Limit #2Refer to page 7-8 for safety limit operation.Harvest time exceeds 3.5 minutes

Strany 76

Section 7 . Refrigeration System Part Number 80-1558-3 7-11ANALYZING DISCHARGE PRESSUREDURING FREEZE OR HARVEST CYCLEProcedure1. Determine the ice mac

Strany 77

. Refrigeration System Section 77-12 Part Number 80-1558-3ANALYZING SUCTION PRESSUREDURING FREEZE CYCLEThe suction pressure gradually drops throughout

Strany 78

Section 7 . Refrigeration System Part Number 80-1558-3 7-13Freeze Cycle Suction Pressure High ChecklistFreeze Cycle Suction Pressure Low ChecklistNOTE

Strany 79

General Information Section 11-2 Part Number 80-1558-3AccessoriesContact your Manitowoc distributor for these optional accessories:BIN CASTERReplaces

Strany 80

. Refrigeration System Section 77-14 Part Number 80-1558-3SINGLE EXPANSION VALVE ICE MACHINES -COMPARING EVAPORATOR INLET AND OUTLET TEMPERATURESNOTE:

Strany 81

Section 7 . Refrigeration System Part Number 80-1558-3 7-15HARVEST VALVE TEMPERATURE CHECKGeneralA harvest valve requires a critical orifice size. Thi

Strany 82 - √) in the small boxes

. Refrigeration System Section 77-16 Part Number 80-1558-3HOW TO USE THE REFRIGERATION SYSTEMOPERATIONAL ANALYSIS TABLESGeneralThese tables must be us

Strany 83

Section 7 . Refrigeration System Part Number 80-1558-3 7-17REFRIGERATION SYSTEM OPERATIONAL ANALYSIS TABLES S Models Single Expansion ValveThis table

Strany 84 - Diagnostics

. Refrigeration System Section 77-18 Part Number 80-1558-3Pressure Control Specifications and DiagnosticsHIGH PRESSURE CUT-OUT (HPCO) CONTROLFunctionS

Strany 85 - Refrigerant Pressure Charts

Section 7 . Refrigeration System Part Number 80-1558-3 7-19Cycle Time/24 Hour Ice Production/Refrigerant Pressure ChartsThese charts are used as guide

Strany 86

. Refrigeration System Section 77-20 Part Number 80-1558-3Refrigerant Recovery/Evacuation and RechargingNORMAL SELF-CONTAINED MODEL PROCEDURESRefriger

Strany 87

Section 7 . Refrigeration System Part Number 80-1558-3 7-21Self-Contained Charging Procedures1. Be sure the toggle switch is in the OFF position.Figur

Strany 88

. Refrigeration System Section 77-22 Part Number 80-1558-3Figure 7-9. Recovery/Evacuation ConnectionsxxxSCHRAEDER FITTINGQUICK CONNECTDISCHARGE LINECO

Strany 89

Section 7 . Refrigeration System Part Number 80-1558-3 7-23SYSTEM CONTAMINATION CLEAN-UPGeneralThis section describes the basic requirements for resto

Strany 90

Section 1 General Information Part Number 80-1558-3 1-3Model/Serial Number LocationThese numbers are required when requesting information from your lo

Strany 91

. Refrigeration System Section 77-24 Part Number 80-1558-3Mild System Contamination Cleanup Procedure1. Replace any failed components.2. If the compre

Strany 92

Section 7 . Refrigeration System Part Number 80-1558-3 7-2510. Follow the normal evacuation procedure, except replace the evacuation step with the fol

Strany 93

. Refrigeration System Section 77-26 Part Number 80-1558-3Figure 7-10. Using Pinch-Off ToolSV1406

Strany 94

Section 7 . Refrigeration System Part Number 80-1558-3 7-27FILTER-DRIERSThe filter-driers used on Manitowoc ice machines are manufactured to Manitowoc

Strany 95

. Refrigeration System Section 77-28 Part Number 80-1558-3REFRIGERANT DEFINITIONSRecoverTo remove refrigerant, in any condition, from a system and sto

Strany 96

Section 7 . Refrigeration System Part Number 80-1558-3 7-29REFRIGERANT RE-USE POLICYManitowoc recognizes and supports the need for proper handling, re

Strany 97 - Part Number 80-1558-3 7-31

. Refrigeration System Section 77-30 Part Number 80-1558-3HFC REFRIGERANT QUESTIONS AND ANSWERSManitowoc uses R-404A and R-134A HFC refrigerants with

Strany 98

Section 7 . Refrigeration System Part Number 80-1558-3 7-31THIS PAGE INTENTIONALLY LEFT BLANK

Strany 99

. Refrigeration System Section 77-32 Part Number 80-1558-3THIS PAGE INTENTIONALLY LEFT BLANK